INSTEK GDM-8145 CALIBRATION and INSTEK GDM-8145 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GDM-8145 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   INSTEK GDM-8145 (GDM8145)   Description / Specification:    
INSTEK GDM-8145 3 1/2 Digit Benchtop Digital Multimeter

The GW Instek GDM-8145 Multimeter with 3 1/2 digits, 0.5" LED display in a distinctive red color measures DC Voltage/Current, AC Voltage/Current with true RMS, Resistance and Diode Test. The true RMS AC and AC+DC response give accurate measurements for equivalent DC energy regardless of the waveform shape. Small voltage offsets are canceled by the auto-zero circuit, and protection mechanisms are available for the entire measurement range. Specifications. DC Voltage range: 200 mV, 2 V, 20 V, 200 V, 1000 V. DC Voltage range accuracy: ±(0.03% of reading + 4 digits). AC Voltage Range (AC or AC + DC True RMS): 200 mV, 2 V, 20 V, 200 V, 1000 V. DC Current range: 200 µA, 2 mA, 20 mA, 200 mA, 2 A, 20 A. DC Current Accuracy: 200 µA to 200 mA ±(0.2% of reading + 2 digits), 2 A to 20 A ±(0.3% of reading + 2 digits). AC Current range: 200 µA, 2 mA, 20 mA, 200 mA, 2 A, 20 A. Resistance Range: 200 ohm, 2 K, 20 K, 200 K-ohm, 2 M, 20 M-ohm. Diode Test Current: Max. 1 mA. Diode Test Open Voltage: Max. 13V.



 

Standard Calibration $70.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GDM-8145. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your INSTEK GDM-8145 CALIBRATION and/or INSTEK GDM-8145 3 1/2 Digit Benchtop Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: